Choose a state

CMC-D Mechanical Fire Sprinklers and Fire Protection Contractor (2023-08-11)

08/11/202308/11/202305Questions - 77
Minimum Passing Score of 73%
Time Allowed - 195 Minutes

The reference material listed below was used to prepare the questions for this examination.  The examination may also contain questions based on trade knowledge or general industry practices. Except for Code books, you can base your answers on later editions of references as they become available.  For Code questions, the examinations will be based only on the edition of the Code book that is listed.

These products apply to test outline dated 2023-08-11

Click Here to View the Candidate Information Bulletin Click Here to View the Candidate Information Bulletin



Open Book These books are allowed while taking your test.
Closed Book These books are for pre-test study only and are not available for use during the test.
In Stock These books are currently in stock.
Out of Stock These books are currently out of stock.

  • Open Book Out of Stock

    NFPA 13D: Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes 2010

    Publication Year: 2010

    $61.87

    Requirements address automatic sprinkler system design, installation, and maintenance including numerous issues such as component listing, hydrostatic tests, sprinkler temperature ratings, design documentation, and hydraulic calculations. - See more at: http://www.nfpa.org/codes-and-standards/document-information-pages?mode=code&code=13D#sthash.1n22iDLJ.dpuf

  • Open Book In Stock

    NFPA 13R: Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies 2010

    Publication Year: 2010

    $125.00

    Requirements concern automatic sprinkler system design, installation, and maintenance including component listing, hydrostatic tests, sprinkler temperature ratings, design documentation, aboveground pipe and equipment, underground pipe, pre-engineered systems, water supply sources, multipurpose piping systems, and hydraulic calculations.

  • Open Book In Stock

    NFPA 22: Standard for Water Tanks for Private Fire Protection 2013

    2013 Edition

    $149.00

    This standard provides requirements for the design, construction, installation, and maintenance of tanks and accessory equipment that supply water for private fire protection.

  • Open Book In Stock

    NFPA 13: Standard for the Installation of Sprinkler Systems 2010

    Publication Year: 2010

    $120.04

    The 2010 NFPA 13: Installation of Sprinkler Systems is revised and updated with added criteria based on recent fire testing and studies performed by the Fire Protection Research Foundation. Chapter 20: Special Designs of Storage Protection presents requirements for the protection of three new special storage arrangements, including carton records storage with catwalk access, and high bay records storage. This edition also adopts the SEI/ASCE 7 approach for load calculations and introduces new zone-of-influence tables for Schedule 5 steel pipe, CPVC, and Type M copper tube. An important new method to calculate rack shelf area takes the placement of loads into consideration.

  • Open Book In Stock

    NFPA 11: Standard For Low, Medium And High Expansion Foam 2016

    2016 Edition

    $150.00

    This standard covers the design, installation, operation, testing, and maintenance of low-, medium-, and high-expansion foam systems for fire protection. Criteria apply to fixed, semi-fixed, or portable systems for interior and exterior hazards

  • Open Book In Stock

    NFPA 12:Standard On Carbon Dioxide Extinguishing Systems 2011

    Publication Year: 2011

    $150.00

    1.1* Scope. 1.1.1 This standard contains minimum requirements for carbon dioxide fire-extinguishing systems. 1.1.2 This standard includes only the necessary essentials to make it workable in the hands of those skilled in this field. A.1.1 Portable carbon dioxide equipment is covered in NFPA 10. The use of carbon dioxide for inerting is covered in NFPA 69.

  • Open Book Out of Stock

    NFPA 2001:Standard on Clean Agent Fire Extinguishing Systems 2012

    2012 Edition

    $149.00

    1.1 Scope. This standard contains minimum requirements for total flooding and local application clean agent fire extinguishing systems. It does not cover fire extinguishing systems that use carbon dioxide or water as the primary extinguishing media, which are addressed by other NFPA documents.

  • Open Book In Stock

    NFPA 25: Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems 2008

    2008 Edition

    $149.00

    1.1* Scope. This document establishes the minimum requirements for the periodic inspection, testing, and maintenance of water-based fire protection systems, including land-based and marine applications.

  • Open Book In Stock

    NFPA 15: Water Spray Fixed Systems for Fire Protection 2007

    2007 Edition

    $149.00

    1.1 Scope. 1.1.1 This standard provides the minimum requirements for the design, installation, and system acceptance testing of water spray fixed systems for fire protection service and the minimum requirements for the periodic testing and maintenance of ultra high-speed water spray fixed systems. 1.1.2* Water spray fixed systems shall be specifically designed to provide for effective fire control, extinguishment, prevention, or exposure protection. 1.1.3* This standard shall not apply to water spray protection from portable nozzles, sprinkler systems, monitor nozzles, water mist suppression systems, explosion suppression, or other means of application covered by other standards of NFPA.

  • Open Book In Stock

    NFPA 101: Life Safety Code, 2012 Edition

    2012 Edition

    $165.00

    The Life Safety Code is the most widely used source for strategies to protect people based on building construction, protection, and occupancy features that minimize the effects of fire and related hazards. Unique in the field, it is the only document that covers life safety in both new and existing structures.

  • Open Book In Stock

    NFPA 20: Standard for the Installation of Stationary Pumps for Fire Protection, 2013 Edition

    2013 Edition

    $150.00

    1.1* Scope. A.1.1 For more information, see NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, and NFPA 70, National Electrical Code, Article 695. 1.1.1 This standard deals with the selection and installation of pumps supplying liquid for private fire protection. 1.1.2 The scope of this document shall include liquid supplies; suction, discharge, and auxiliary equipment; power supplies, including power supply arrangements; electric drive and control; diesel engine drive and control; steam turbine drive and control; and acceptance tests and operation. 1.1.3 This standard does not cover system liquid supply capacity and pressure requirements, nor does it cover requirements for periodic inspection, testing, and maintenance of fire pump systems. 1.1.4 This standard does not cover the requirements for installation wiring of fire pump units.